FAQ: How To Clean A Thermocouple On A Patio Heater?

How do you clean a thermocouple?

The best way to clean your thermocouple is to use either a piece of steel wool or the coarse side of a sponge to gently clean off any soot or other remnants. You can use a pencil eraser to clean between the threads of the screw that connects the thermocouple to the control valve of your system.

How do you clean a propane thermocouple?

The thermocouple in a propane patio heater can easily be cleaned by removing it from the pilot assembly and use a sponge, steel wool or other abrasive material to scrub and dislodge any accumulated debris.

What does a patio heater thermocouple look like?

The thermocouple looks like a piece of metal tubing smaller than a soda straw. To find it, first locate the gas control box. This is the box that the main gas line enters, where you turn the gas on in the furnace. The other end of the thermocouple sits in the flame of the pilot light.

You might be interested:  Question: How To Vent A Propane Water Heater?

Can you clean a thermocouple and make it work?

It’s easy to clean a furnace thermocouple, and all you need is a little elbow grease and an emery cloth. You won’t need any special solutions or tools for this job.

How do you know if you have a bad thermocouple?

If you can’t get the flame to light at all, and you’re sure the gas is on, there’s probably an obstruction in the pilot tube. If the flame lights and goes out when you release the gas control knob after holding it in for the recommended 20 to 30 seconds, that’s the sign of a thermocouple malfunction.

How often should you replace a thermocouple?

The thermocouple unwinds and switches on the fireplace. Thermocouples are rigorously tested and should last for years. Indeed, experts believe a four-year check cycle is all that is needed to make sure things are functioning properly.

How do you bypass the thermocouple on a propane fire pit?

To bypass the thermocouple:

  1. Move the tilts switch wire aside.
  2. Remove your thermocouple from the heater using an 8mm wrench.
  3. Pull the valve housing aside using your 13mm socket wrench.
  4. Remove the valve using your pliers.
  5. Put your thermocouple back into position.

What is a thermopile vs thermocouple?

The main difference between Thermocouple and Thermopile is their method of measurement. The thermocouple is a thermoelectric instrument, while the thermopile is an instrument that modifies thermal energy into electrical output.

Why does my propane wall heater keep going out?

The thermocouple is the heat-sensitive safety device that prevents the release of unburned gas. If the thermocouple is too far from the flame, this can cause the pilot to go out and shut down the propane heater; you can fix this easily by moving the thermocouple closer to the flame.

You might be interested:  FAQ: Which Type Of Space Heater Is Best?

What makes a thermocouple go bad?

Changes in temperature can cause regular expansion and contraction in metal, which will cause thermocouples to weaken over time. After enough time, metal fatigue can cause a thermocouple to break. If thermocouples start to give out unusual readings, it may be suffering from metal fatigue.

Can you manually light a patio heater?

Ensure there are no leaks and the heater is in good repair. For automatic ignition systems, hold the control knob in and use a lighter to ignite the flame. For non-automatic systems, turn the control knob to the lowest setting and use a lighter to ignite the flame.

Can you fix a thermocouple?

If the pilot lights but the flame goes out as soon as you release the button after holding it for 60 seconds, then the thermocouple is bad. It’s possible to replace the thermocouple without removing the burner assembly, and many repair people do this.

How do you fix a pilot light that keeps going out?

What do I do if my pilot light keeps going out?

  1. Find the gas shut-off knob and turn to the “Off” setting.
  2. Remove the access panel to access the burner.
  3. Turn the knob to “Pilot” to start the flow of gas.
  4. While still holding the gas knob, light the pilot with a long lighter.

What do you do if your pilot light won’t stay lit?

How to Light Your Furnace’s Pilot

  1. Make sure the thermostat is in heat mode.
  2. Locate the pilot valve.
  3. Always turn the valve knob to the off position and make sure to wait at least several minutes for any residual gas to clear away.
  4. Get your match ready.
  5. Once the pilot stays lit, turn the pilot valve to the on position.

Leave a Reply