FAQ: How To Clean Water Heater Thermocouple?

How do you clean a thermocouple?

The best way to clean your thermocouple is to use either a piece of steel wool or the coarse side of a sponge to gently clean off any soot or other remnants. You can use a pencil eraser to clean between the threads of the screw that connects the thermocouple to the control valve of your system.

How do I know if my thermocouple is bad on my water heater?

If the pilot lights but the flame goes out as soon as you release the button after holding it for 60 seconds, then the thermocouple is bad. It’s possible to replace the thermocouple without removing the burner assembly, and many repair people do this.

Can you light a water heater with a bad thermocouple?

However, if the thermocouple is faulty, the gas valve will not open, which can prevent the pilot light from being lit. This will typically require a professional plumber to correct the problem.

You might be interested:  Question: How To Install Wall Heater?

Do thermocouples need cleaning?

If the Thermocouple is faulty it will cause the unit to shut down. How to clean? Remove Thermocouple from pilot assembly, using steel wool or emery cloth to lightly clean the tip removing any soot or build up that might have accorded due to an improper pilot flame.

How long do thermocouples last?

All things considered, the question remains, “How long should my thermocouple last?” The answer to that question is that it depends on the application. In an ideal environment, that length of time can be indefinite.

What are the symptoms of a bad thermocouple?

Failed Thermocouple Symptoms

  • Signs of contamination on the tube, e.g. discoloration, cracks, or pinholes.
  • Signs of wear or corrosion of the wirings, e.g. missing insulation or bare wire.
  • Physical damage to the connectors which can have an effect on the reliability of the test reading.

How do you check if a thermocouple is working?

If the thermocouple is working, you should be able to measure 30 to 40 millivolts of voltage at the connection end of the tube when the pilot flame is on. You can test this yourself using a multimeter, but you may need a helper to keep the pilot flame burning while you do it.

Can you replace a thermocouple yourself?

The No. 1 cause of pilot lights that won’t stay lit is a worn-out thermocouple. It’s easy to replace and a new one costs $5 to $10. Then unfasten the three nuts that hold the thermocouple and the two gas tubes to the valve.

You might be interested:  FAQ: When To Replace Electric Water Heater?

Why do thermocouples go bad?

Changes in temperature can cause regular expansion and contraction in metal, which will cause thermocouples to weaken over time. After enough time, metal fatigue can cause a thermocouple to break. If thermocouples start to give out unusual readings, it may be suffering from metal fatigue.

How do you fix a pilot light that keeps going out?

What do I do if my pilot light keeps going out?

  1. Find the gas shut-off knob and turn to the “Off” setting.
  2. Remove the access panel to access the burner.
  3. Turn the knob to “Pilot” to start the flow of gas.
  4. While still holding the gas knob, light the pilot with a long lighter.

How much does it cost to replace a water heater thermocouple?

Thermocouple – $20 to $150 The thermocouple is an apparatus that senses whether the pilot light is lit and triggers the gas control valve. Repairs typically cost about $150 to have it done professionally, though a new thermocouple itself only costs about $20 on average.

Why does my pilot light keep going out on water heater?

If the pilot light goes out, the thermocouple senses the drop in temperature and signals for the gas valve to close. If you have a faulty thermocouple is the most common reason that your pilot light is malfunctioning. Over time your water heater will collect dirt, dust and other kinds of debris.

Can I manually light my gas water heater?

Lighting the Pilot Light on a Manual Hot Water Heater If your hot water heater is a manual, grab a long lighter. Turn the pilot dial to the off position and wait 5-10 minutes for any gas to dissipate. Then, turn the pilot dial until it says the word pilot. After that, set your temperate knob to low.