FAQ: What Size Breaker For Water Heater?

What size breaker do I need for a 40 gallon water heater?

A 40-gallon water heater should have an average 4500 Watt capacity and 240 V emf. Thus, a 25 or 30A breaker is sufficient for a 40-gallon breaker. However, for your safety, we recommend getting a 30A breaker.

Can I use a 40 amp breaker for a water heater?

You cannot put a 40A breaker on #10 wire. If you are sure there is (at least) #8 wire all the way from the breaker to the water heater, you can just replace the 30A breaker with a 40A breaker, but if and only if you have verified the size of the wire throughout the entire circuit.

What size breaker should a hot water heater be on?

A 240-volt dedicated circuit is needed for electric water heaters to work. A 30-amp double-pole breaker and 10-2 non-metallic cable are included in the circuit wiring.

You might be interested:  Readers ask: Where Can I Find A Portable Car Heater?

What size breaker do you need for a 50 gallon electric water heater?

The standard for water heater circuits is #10, two conductors with ground (10/2) and a 30 amp circuit breaker for a water heater.

What wire do I use for a 30 amp breaker?

“Twelve-gauge wire is good for 20 amps, 10-gauge wire is good for 30 amps, 8-gauge is good for 40 amps, and 6-gauge is good for 55 amps,” and “The circuit breaker or fuse is always sized to protect the conductor [wire].”

Can you use 12 2 wire for a water heater?

A 12-2 w/ground should be enough, although I would use a 10/2 for future “upgradability”. 10/2 is the standard cable for a water heater. Connect white to red. 12/2 would be insufficient for almost all water heaters.

What size breaker do I need for a 4500 watt water heater?

30 Amp dual pole breaker and 10 Gage wire size are required for 4500 watt elements.

Can I replace a 30 amp breaker with a 60 amp breaker?

It’s necessary to have at least 6 wire for a 60 Amp breaker. I believe the OP is thinking of doubling the capacity of the single breaker. When he returns with pictures, we’ll see. The answer isn’t yes.

How many amps does a 50 gallon water heater pull?

A typical 50 gallon electric water heater runs at 4500 watts. In an electric circuit of 240 volts, 4500 watts is equivalent to 18.75 amps.

What is the downside of an electric tankless water heater?

Tankless water heaters produce an endless supply of hot water, take up less space, have a lower risk of leaking, are safer, and have a significantly longer lifespan on average. The main disadvantage of tankless water heaters is their upfront cost (unit and installation) is significantly higher than tank-style heaters.

You might be interested:  How To Properly Vent A Gas Water Heater?

Does a tankless gas water heater need a dedicated circuit?

Does a tankless gas water heater need a dedicated circuit? Gas tankless water heaters use just a tiny amount of amperage to ignite the flame. Unless the manufacturer requires it, there is no need for a dedicated circuit.

How many amps does a 6 gallon hot water heater draw?

6 gal., 120 VAC, 16.7 A Amps, Residential Mini Tank Water Heater.

What size breaker do I need for a 220 water heater?

Electric Range – 220 – 240 volt, 60 hertz, properly grounded circuit with 40 amp breaker or fuse protection with #8 gauge wire. With a 50 amp breaker, # 6 gauge wire is required.

What size breaker do I need for a 220 volt water heater?

Electric water heaters use anything between 220 to 250 volts of alternating current. You’ll need a double circuit breaker that is correctly rated for the power draw of the water heater. We’re looking at between 20 Amp and 30 Amp for most electric water heaters.