Often asked: How To Light A Gas Water Heater?

How do you light a pilot light on a gas water heater?

How to Light a Water Heater Pilot Light

  1. Open the door/cover over the pilot light access.
  2. Use a flashlight or a headlamp to find the burner inside.
  3. Turn the gas knob to “Pilot,” press and hold it down.
  4. While still holding the gas down, light that pilot.

How do you light a gas water heater?

Turn the water heat dial to Low and the On/Off/Pilot dial to Pilot. Then, turn the On/Off/Pilot dial downwards and push the igniter button at the same time. Let go of the igniter button, but keep pressing the Pilot dial downward for around 30 seconds. You should hear a “whoosh” sound when the gas is lit.

Can I manually light my gas water heater?

Lighting the Pilot Light on a Manual Hot Water Heater If your hot water heater is a manual, grab a long lighter. Turn the pilot dial to the off position and wait 5-10 minutes for any gas to dissipate. Then, turn the pilot dial until it says the word pilot. After that, set your temperate knob to low.

You might be interested:  Readers ask: What Is A Ceramic Space Heater?

Can I relight the pilot light by myself?

If your pilot light goes out, your furnace will not be able to produce heat because its burners will not ignite. Often, homeowners can relight the pilot themselves.

Should pilot light always be on water heater?

The pilot should be on the water heating the house. The pilot flame can be difficult to see through a window. To know if the pilot is on or off, you need to remove the access door and shield and look at the burner and pilot through it.

How long should a gas water heater stay on?

Water heaters run an average of three hours a day, but the difference in total operation time can range from one or two hours for new tankless heaters to five or more for older standby tanks.

Who do I call for water heater problems?

But for the most part, you should call a licensed plumber for all hot water heater problems.

Is there a pilot light on a water heater?

The water heater pilot light is a small flame that ignites the gas burner on your water heater. When the water heater pilot light goes out, first try relighting it, following the directions on the water heater label.

How do you know if you have a bad thermocouple?

If you can’t get the flame to light at all, and you’re sure the gas is on, there’s probably an obstruction in the pilot tube. If the flame lights and goes out when you release the gas control knob after holding it in for the recommended 20 to 30 seconds, that’s the sign of a thermocouple malfunction.

You might be interested:  FAQ: How To Get Air Out Of Hot Water Heater?

What would cause the pilot light to go out on a gas water heater?

Some of the most common reasons that water heater pilot lights go out include: A faulty thermocouple. Over time, thermocouples can begin to malfunction and shut off the gas supply to the pilot light even if it’s burning properly. A bent or dirty thermocouple.

How do you light a gas hot water heater without an igniter?

Lighting with No Igniter

  1. Take a long lighter to reach the pilot.
  2. Remove the plate attached below the dial box.
  3. Switch Pilot to OFF.
  4. Wait for a while, – 5-10 minutes until there won’t be any gas.
  5. Change the temperature to LOW, and switch to Pilot.
  6. Push ON/OFF dial down, and simultaneously use the lighter.

Does gas still flow when pilot light goes out?

If your pilot light repeatedly goes out, this is a likely culprit. If this flame sensor should fail, gas will continue to flow even after the pilot light has been extinguished, causing a safety hazard, and requiring immediate repair.

How much does it cost to relight a water heater?

Pilot Light Assessment and Reignition Cost If you follow safe procedures, you can relight this component on your own. This would save you a service call fee, which could range from $45 to $150 per hour. If it doesn’t light, you could have thermocouple or valve issues.