Often asked: What Amp Breaker For Hot Water Heater?

What size breaker do I need for a 40 gallon water heater?

A 40-gallon water heater should have an average 4500 Watt capacity and 240 V emf. Thus, a 25 or 30A breaker is sufficient for a 40-gallon breaker. However, for your safety, we recommend getting a 30A breaker.

Can you use a 50 amp breaker for a water heater?

In an electric circuit of 240 volts, 4500 watts is equivalent to 18.75 amps. This means that a 50 gallon water heater will not flip a circuit breaker of 20 amps, but it will force the circuit breaker to operate at 95% of its capacity, something most circuit breakers are not qualified to do.

Can I use a 40 amp breaker for a water heater?

You cannot put a 40A breaker on #10 wire. If you are sure there is (at least) #8 wire all the way from the breaker to the water heater, you can just replace the 30A breaker with a 40A breaker, but if and only if you have verified the size of the wire throughout the entire circuit.

You might be interested:  How To Turn Up The Hot Water Heater?

What size breaker do I need for a 30 gallon water heater?

The branch circuit needs to be calculated at 125% of the rated ampacity for this type of water heater to be considered a continuous load. In order to work on a 20 Amp OCPD, you will need a 25 or 30 Amp circuit.

How many amps does a 40 gallon electric water heater draw?

Depending on the code, a 2500w heater w/240v will draw 2500/240 or 18.75 Amps and either 25 or 30 Amps.

How many amps does a 40 gallon hot water tank use?

Bottom line, For a 4500w heater w/240v it will draw 4500/240 or 18.75 amps so #10 wire and either 25 or 30 amp breaker, depending on code.

How many amps does a 60 gallon water heater use?

Requires 240 volt electricity (a 30 amp breaker, with 10 gauge wire from the panel). Also available in a BC compliant model. Performance 60 Gal Electric Water Heater with 6 Year Warranty is rated 3.5 out of 5 by 6.

What size breaker do I need for 4500 watts?

30 Amp dual pole breaker and 10 Gage wire size are required for 4500 watt elements.

What size breaker do I need for a 50 gallon water heater?

The standard for water heater circuits is #10, two conductors with ground (10/2) and a 30 amp circuit breaker for a water heater. If you are running cable anyway, just run #10 and replace the breaker so it’s done right, once and for all.

How many amps does a 80 gallon water heater pull?

This should be checked out first. A water heater will only draw depending on the wattage of the element(s). So your WH has 2 – 4500 watt elements. When only one runs it is drawing about 22 amps (208 is nominal voltage which is what you have in your building) 4500/208= 21.6 amps.

You might be interested:  Quick Answer: How To Install A Power Vent Water Heater?

What size wire should be used with a 30 amp breaker?

RULES OF THUMB. Many techs will repeat these rules of thumb and rely on them in all circumstances: “Twelve-gauge wire is good for 20 amps, 10-gauge wire is good for 30 amps, 8-gauge is good for 40 amps, and 6-gauge is good for 55 amps,” and “The circuit breaker or fuse is always sized to protect the conductor [wire].”

What is the downside of an electric tankless water heater?

Tankless water heaters produce an endless supply of hot water, take up less space, have a lower risk of leaking, are safer, and have a significantly longer lifespan on average. The main disadvantage of tankless water heaters is their upfront cost (unit and installation) is significantly higher than tank-style heaters.

How many amps does a 28 gallon water heater use?

The amperage is vital to ensure you do not overload your current home’s electrical system. The standard amperage for an electric water heater is 18.8 Amps with 240Volts, 4500 Watt. A gas water heater in average uses less than 12 Amps with 115Volts (US and Canada).

What size breaker does a water heater need?

Electric water heaters require a 240-volt dedicated circuit, which serves only the water heater and no other appliances or devices. The circuit wiring typically includes a 30-amp double-pole breaker and 10-2 non-metallic (NM) or MC cable.