Readers ask: What Wire For Hot Water Heater?

Can I use 10 3 wire for a hot water heater?

All you need is 2 insulated conductors and 1 ground conductor. Since you have already bought 10-3 cable, I would just cap off the white conductor at both ends and use the red and black conductors for your hot wires and the ground conductor to attach to the green screw on the water heater.

Can you use 12 2 wire for a water heater?

A 12-2 w/ground should be enough, although I would use a 10/2 for future “upgradability”. 10/2 is the standard cable for a water heater. Connect white to red. 12/2 would be insufficient for almost all water heaters.

Can I use 10-2 wire for a water heater?

Most water heaters are wired with 10-2 w/Ground shielded cable. For long distances you may need to go with heavier wire. When you use this type of wire both the white and the black will serve as hot conductors. The bare ground wire will also be connected to the neutral lug.

You might be interested:  Quick Answer: Where Is The Heater Core?

What size wire do I need for a 50 gallon water heater?

The standard for water heater circuits is #10, two conductors with ground (10/2) and a 30 amp circuit breaker for a water heater. If you are running cable anyway, just run #10 and replace the breaker so it’s done right, once and for all.

Can you use 12 2 wire for 220?

The same 12-gauge wire can be used for a 220v, 20-amp outlet to run power tools. You need a different type of receptacle and 10-gauge cable if the appliance draws 30 Amps.

Can you wire a 10-2 dryer?

If your dryer does not require the neutral, and is a pure 220V appliance, than you can use the 10-2 and be code compliant. The only issue is sharing the neutral and the ground.

How many amps does a 60 gallon water heater use?

Requires 240 volt electricity (a 30 amp breaker, with 10 gauge wire from the panel). Also available in a BC compliant model. Performance 60 Gal Electric Water Heater with 6 Year Warranty is rated 3.5 out of 5 by 6.

How many amps does a 50 gallon water heater pull?

A typical 50 gallon electric water heater runs at 4500 watts. In an electric circuit of 240 volts, 4500 watts is equivalent to 18.75 amps.

What size breaker do I need for a tankless water heater?

What size breaker and wire for tankless? Single wire cannot be split apart to connect to multiple terminals. Typical tankless requires 40-50 amp breaker for each wire.

Does a 240V water heater need a neutral?

For a true 240V load (no 120V components) there is no need for neutral. For those loads, a /2 cable with hot white and hot black is the norm.

You might be interested:  What Happens When Your Heater Core Goes Out?

Does a hot water heater need a ground wire?

It should be noted that the National Electric Code does not require a bonding wire on a water heater. Note that a plumbing system with PEX or other forms of plastic water supply pipe does not require any kind of electrical grounding.

Can you wire a hot water heater backwards?

Can you wire a hot water heater backwards? Yes, you can get it with minimal effects. If the 220v heater has red and black wiring, it can be wired backwards. As much as this is possible, you must ensure you correctly wire the hot water heater to avoid water polarity issues.

How many amps does a hot water heater require?

Most electric hot water heaters are designed for 240 VAC. The de facto standard size heating element is 4,500 watts, which corresponds to 18.8 amps and 12.8 ohms.

What size breaker do I need for a 4500 W water heater?

30 Amp dual pole breaker and 10 Gage wire size are required for 4500 watt elements.