Why Is My Heater Blowing Cold Air?

What do I do if my heater is blowing cold air?

When your furnace blows cold air, try turning the heating unit off and on. If the air feels warm for a moment or two, then switches to cold, it may be that the flame sensor is dirty. With a dirty flame sensor, your gas burner won’t stay lit, causing the air to go cold soon after the furnace turns on.

Why is my furnace running but no heat?

Furnace filters Dirty filters are the most common cause of furnace problems. Dust and dirt restrict airflow—and if the filter gets too clogged, the heat exchanger will overheat and shut off too quickly, and your house won’t warm up. If the blower is running but no heat is coming out, replace the filter.

Why is my heater not blowing out hot air?

First, check to make sure the thermostat is set correctly. You will want to make sure that the fan control is set to auto, and not ‘on’. If the thermostat appears set correctly, turn off your heater at the thermostat and check the filter. If the filter is dirty, replace it.

You might be interested:  Often asked: How To Replace Pressure Relief Valve On Water Heater?

What to check if heat is not working?

Check the Batteries in Your Thermostat If your thermostat runs on batteries, try replacing them. You’d be surprised how many times this simple fix gets a heater going again. It may sound like a no-brainer, but you do need to turn your thermostat to the “heat” or “automatic” setting before your heater will click on.

Can a dirty furnace filter cause no heat?

Dirty furnace filters Is your furnace firing up but not blowing heat as hard as normal? That’s because air filters trap dust, dirt and debris like hair, which over time can restrict or block vital air flow, overheating the heat exchanger and preventing your furnace from working as it should.

How do I reset my heater?

How to Reset an Electric Furnace

  1. First, turn off the power supply to the furnace by turning off the breaker in the circuit box.
  2. Locate the reset button on the furnace and press it to reset the furnace.
  3. If the button is popped up, press it down.
  4. Return the cover to the blower compartment and turn the power on.

Why my heater is not working?

Often, the issue is that the heating system is simply dirty. If your furnace has a dirty blower, the blower could cause equipment failure. In short, a dirty blower can cause the heat exchanger to fail. Dirty air filters could also be the reason your heater stopped working.

How do I reset my central heating system?

To reset the unit via wall control, turn the control OFF at the control, wait for thirty seconds, then turn the control ON. If there is no persisting problem, your unit should restart and work fine. If the issue persists, it’s time to call a service technician to assess the components.